Size | Power rating P70 (mW) |
Max. working voltage (V) | Ranges / Tolerances / TCR / VCR | |||||
trimmed | untrimmed | 100M-500M | 500M-1G | 1G-10G | 10G-100G | 100G-1T | ||
0402 | 50 | 30 | 90 | 5/10/20% TC100/250 <1000ppm/V |
5/10/20% TC250/500 <1000ppm/V |
10/20/30% TC1000/2000 <2000ppm/V |
/ | / |
0603 | 75 | 75 | 200 | 5/10/20% TC100/250 <500ppm/V |
5/10/20% TC250/500 <500ppm/V |
5/10/20/30% TC500/1000 <2000ppm/V |
10/20/30% TC1000/2000 <3000ppm/V |
10/20/30% TC3000 <5000ppm/V |
0805 | 125 | 100 | 300 | 5/10/20% TC100/250 <250ppm/V |
5/10/20% TC250/500 <250ppm/V |
5/10/20% TC500/1000 <1000ppm/V |
10/20/30% TC1000/2000 <5000ppm/V |
10/20/30% TC3000 <10000ppm/V |
1206 | 250 | 200 | 600 | 5/10/20% TC50/100/250 <100ppm/V |
5/10/20% TC100/250 <100ppm/V |
5/10/20% TC500/1000 <1000ppm/V |
10/20/30% TC1000/2000 <2000ppm/V |
10/20/30% TC3000 <5000ppm/V |
1210 | 350 | 300 | 900 | 5/10/20% TC50/100/250 <100ppm/V |
5/10/20% TC100/250 <100ppm/V |
5/10/20% TC250/500 <500ppm/V |
5/10/20/30% TC500/1000 <1000ppm/V |
5/10/20/30% TC1000/2000 <2000ppm/V |
2512 | 1000 | 1000 | 2000 | 1/5/10/20% TC25/50/100 <25ppm/V |
1/5/10/20% TC100/250 <25ppm/V |
5/10/20% TC250/500 <100ppm/V |
5/10/20/30% TC250/500 <250ppm/V |
5/10/20% TC500/1000 <500ppm/V |
4020 | 1500 | 4000 | 6000 | 1/5/10/20% TC25/50/100 <10ppm/V |
1/5/10/20% TC25/50/100 <10ppm/V |
5/10/20% TC50/100 <25ppm/V |
5/10/20/30% TC100/250 <100ppm/V |
5/10/20% TC250/500 <250ppm/V |
For a better life cycle under normal usage, 50% of the rated power is recommended
* Rated Continuous Maximum Working Voltage (RCWV) should be determined from RCWV =√Power Rating x Resistance Values Max. RCWV listed above.
** Short-time Overload (STOL) test should be determined from STOL=√2.5 x Power Rating x Resistance Values or maximum overload voltage listed above, whichever is lower.